| Paramètre | Valeur |
|---|---|
| When communication unitis connected | |
| Article | Specifications |
| Câble | 0.2 mm22-core (brown and blue lead wires) / 0.15 mm27-core composite cable, 2 m6.562 ftlong |
| Détails | Slave unit / Wire-saving type |
| Produit | Controller |
| Matériel | Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal |
| Poids net | 60 g approx. |
| Numéro de pièce | HG-TC113 |
| 1 à 7 unités | 1 to 6 units |
| Nom du produit | Thru-beam Type Digital Displacement Sensor HG-T |
| 8 à 15 unités | 7 to 14 units |
| Gamme d'affichage | -199.999 to 199.999 mm-7.874 to 7.874 in |
| Taux d'échantillonnage | 1 ms (standard sampling) / 0.5 ms (high-speed sampling) |
| Numéro de produit | HG-TC113 |
| Tension d'alimentation | 24 V DC ±10 %, including ripple 0.5 V (P-P) |
| Degré de pollution | 2 |
| Résolution d'affichage | 1 μm0.039 mil |
| Altitude opérationnelle | 2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
| Consommation de courant | 100 mA or less (when sensor head is connected)(Note) : Current consumption does not include analog current output. |
| Conformité réglementaire | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Tête de capteur applicable | HG-T1010、HG-T1110 |
| Nombre moyen (temps de réponse) | 1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling). |
| Nombre d'unités esclaves connectées | Maximum sink current and sourcecurrent of control output |
| Résistance environnementale : Protection | IP40(IEC) |
| Nombre maximal de contrôleurs connectables | Up to 15 slave units can be connected to a master unit.(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. |
| Résistance environnementale : humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Résistance environnementale : Résistance aux chocs | 98m/s2acceleration (10 G approx.) in X, Y and Z directions five times each |
| Résistance environnementale : Température ambiante | -10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃-4 to +140 ℉(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA |
| Résistance environnementale : Résistance aux vibrations | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each |
| Résistance environnementale : Résistance d'isolation | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Résistance environnementale : tenue en tension | 1,000 V AC for one minute between all supply terminals connected together and enclosure |