| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Taper | NPN output |
| Poids | Net weight: 140 g approx. |
| Détails | Controller (NPN output) |
| Produit | Ultra-compact Laser Collimated Beam Sensor |
| Matériel | Enclosure: Polybutylene terephthalateTransparent cover: Polycarbonate |
| câble d'E/S | 0.09 mm210-core composite cable, 2 m6.562 ftlong |
| Numéro de pièce | HL-AC1 |
| Entrée de réinitialisation | 0 V connection: EffectiveOpen: Ineffective-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
| Nom du produit | Ultra-compact Laser Collimated Beam Sensor HL-T1 |
| Entrée de synchronisation | 0 V connection: EffectiveOpen: Ineffective-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
| Sortie linéaire | Current / voltage output switchable (Note)-During current output: 4 to 20 mA/F.S., Maximum load resistance: 300 Ohm-During voltage output: plus or minus 4 V/F.S., Output impedance 100 Ohm(In the monitor focus function, it can also be set at plus or minus 5 V, 0 to 5 V, etc.)(Note) Switching between current and voltage is accomplished by a switch on the bottom of the controller. |
| Fonctions principales | ・Measured value display・Setting value, light amount value resolution display・Standard received light setting・Automatic scaling・Scaling・Display reverse・ECO display・Display digits limitation・Sample hold・Peak hold・Bottom hold・Peak to peak hold・Self peak hold・Self bottom hold・Zero reset・Initial reset・ON-delay timer・OFF-delay timer・One-shot timer・Differentiation・Sensitivity selection・Threshold value direct setting・Positioning teaching・2-point teaching・Automatic teaching・Hysteresis width variability・Monitor focus・Non-measuring time setting・(A – B) calculation(Note:The calculation unit is necessary.)・(A + B) calculation(Note:The calculation unit is necessary.)・Mutual interference prevention (Note:The calculation unit is necessary.)・Laser deterioration detection・Key lock・Zero reset memory |
| Numéro de produit | HL-AC1 |
| Tension d'alimentation | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Entrée laser désactivée | 0 V connection: Laser emission haltOpen: Laser emission-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
| Cycle de mesure | 150 micro s |
| Degré de pollution | 3 (industrial environment) |
| Entrée de réinitialisation zéro | 0 V connection: Zero reset operatesOpen: Zero reset ineffective-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
| Consommation de courant | 190 mA or less (when connected to the sensor head) |
| rallonge de câble d'E/S | Extension up to total 10 m32.808 ftis possible, with 0.09 mm2or more, cable.(Note) If the extension cable is longer than 10 m32.808 ft, then it will not qualify for CE marking. |
| Affichage sub-numérique | 5 digit yellow LED display[RUN mode: Either the resolution or laser beam reception amount will be displayed. THR mode: The threshold value will be displayed., Reverse mode: The display orientation will be reversed.] |
| Affichage numérique principal | 5 digit red LED display[RUN mode: Either the measured value (mm) or the hold value will be displayed. Reverse mode: The display orientation will be reversed.] |
| résistance d'isolation | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Tête de capteur applicable | HL-T1001A/T1001F, HL-T1005A/T1005F, HL-T1010A/T1010F |
| tenue en tension | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Indicateurs : Activer (ACTIVER) | Green LED (lights up during normal operation) |
| Indicateurs : Résultats des jugements | HIGH: Orange LED (lights up when measured value > HIGH threshold value)PASS: Green LED (lights up when HIGH threshold value >= measured value >= LOW threshold value)LOW: Yellow LED (lights up when LOW threshold value > measured value) |
| Indicateurs : Remise à zéro (ZÉRO) | Green LED (lights up when the zero reset function is enabled) |
| Fréquence d'échantillonnage moyenne paramétrable | 1 / 2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 / 512 / 1,024 / 2,048 / 4,096(Note) The judgment output and linear output and linear output response time is calculated by (Measuring cycle) x (Set average sampling rate + 1). |
| Conformité à la directive de marquage CE | EMC Directive, RoHS Directive |
| Résultats du jugement (HAUT, RÉUSSI, BAS) | NPN open-collector transistor-Maximum sink current: 50 mA-Applied voltage: 30 V DC or less (between judgment output and 0 V)-Residual voltage: 1.2 V or less (at 50 mA sink current) |
| Indicateurs : Laser émetteur (LD ON) | Green LED (lights up during laser emission) |
| Résistance environnementale : humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Résistance environnementale : Résistance aux chocs | 300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each |
| Sortie linéaire : Caractéristiques de température | plus or minus 0.2 % F.S./℃(Note) These are the temperature characteristics of the linear output when the sensor head is connected. |
| Résistance environnementale : Température ambiante | 0 to +50 ℃+32 to +122 ℉(No dew condensation allowed), Storage: -25 to +65 ℃-13 to +149 ℉ |
| Résistance environnementale : Résistance aux vibrations | 10 to 150 Hz frequency, 0.7 mm0.028 indouble amplitude in X, Y and Z directions for 80 min. |
| Sorties de jugement (HIGH, PASS, LOW) : Opération de sortie | HIGH: ON when measured value > HIGH threshold valuePASS: ON when HIGH threshold value >= measured value >= LOW threshold valueLOW: ON when LOW threshold value > measured value |
| Sorties de jugement (HIGH, PASS, LOW) : Nombre de sorties | HIGH / PASS / LOW 3 values output |
| Résultats du jugement (ÉLEVÉ, RÉUSSI, FAIBLE) : Catégorie d'utilisation | DC-12 or DC-13 |
| Sorties de jugement (HAUT, PASS, BAS) : Protection contre les courts-circuits | Incorporated |