Heures de service : Lundi à vendredi 9h00-18h00
UHLC2CP - UHLC2CP HL-C2C-P PANASONIC Control unite HL-C2, high resolution, -5 to +5V, 4-20mA, PNP-type, Export Control
En stock Produit phare

UHLC2CP

UHLC2CP HL-C2C-P PANASONIC Control unite HL-C2, high resolution, -5 to +5V, 4-20mA, PNP-type, Export Control

$0.00USD
3565 en stock
Spécifications clés
Article:Specifications
Poids:450 g approx.
Détails:Controller
Produit:Ultra High-speed High-precision Laser Displacement Sensor
Informations sur le fournisseur
PANASONIC
PANASONIC
Produits : 4316
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
ArticleSpecifications
Poids450 g approx.
DétailsController
ProduitUltra High-speed High-precision Laser Displacement Sensor
MatérielCase: Polycarbonate
AccessoireUSB cable (2 m 6.562 ft long): 1 pc.Short bracket: 1 pc.
Numéro de pièceHL-C2C-P
Entrée de réinitialisationReset is done when connected to external power (+).Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Sortie d'alarmePNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less(between alarm output and +V)- Residual voltage: 1 V or less(at 100 mA source current)
Nom du produitUltra High-speed・High-precision Laser Displacement Sensor HL-C2
Entrée de synchronisationON at/during connection to external power (+)(depending on analysis mode)Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Taux d'échantillonnage10 micro s, 20 micro s, 40 micro s, 100 micro s, 200 micro s, 400 micro s, 1 ms, 2 ms
Sortie stroboscopiquePNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less(between strobe output to +V)- Residual voltage: 1 V or less(at 100 mA source current)
Numéro de produitHL-C2C-P
Tension d'alimentation24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
Entrée zéroZero set is ON when connected with external power (+).Zero set turns to OFF after continuously connected to external power (+) for one second.Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Indicateur : PuissanceGreen LED (lights up at power on)
Consommation de courant500 mA approx. at 2 sensor heads connected350 mA approx. at 1 sensor head connected(100 mA approx. is additionally required when the mini console is connected)
Indicateur : Alarme 1Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Indicateur : Alarme 2Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
Entrée de commande laserLaser emission is stopped when connected to external power (+).Laser is emitted immediately after opened.Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Entrée de modification de la mémoireMemory is specified when connected to external power (+).Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Tête de capteur ConnectaleNumber of connectable units: Max. 2 units.
Entrée de verrouillage à distanceLaser emission is delayed when connected to IL (+).Laser emission stop at openApplied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Sortie analogique : CourantCurrent output scale: 4 to 20 mA/F.S (initial value)Output range during normal status: 2 to 24 mAOutput at abnormal status: 1 mA or 25 mAResolution: 3 micro A, Linearity plus or minus 0.05% F.S.Load impedance: 250 Ohm max., Response delay time: 10 micro s approx.(Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
Sortie analogique : TensionVoltage output scale: -5 to +5 V/F.S (initial value)Output range during normal status: -10.0 to +10.0 VOutput at abnormal status: -10.8 V or +10.8 VResolution: 2 mV, Linearity: plus or minus 0.05 % F.S.Max. 2 mA, output impedance 50 Ohm , Response delay time: 1.5 micro s/V approx.(Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
Résultat du jugement (HI, GO, LO)PNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less(between judgment output to +V)- Residual voltage: 1 V or less(at 100 mA source current)
Sortie d'alarme : Fonctionnement de sortieOpened when the amount of light is insufficient
Sortie stroboscopique : Fonctionnement de sortieOpened at data determination
Sortie d'alarme : Protection contre les courts-circuitsIncorporated
Sortie stroboscopique : Protection contre les courts-circuitsIncorporated
Indicateur : Tête de capteur A Rayonnement laserGreen LED (lights up during or immediately before laser emission of sensor head A)
Indicateur : Rayonnement laser de la tête de capteur BGreen LED (lights up during or immediately before laser emission of sensor head B)
Résistance environnementale : humidité ambiante35 to 85 %RH
Résistance environnementale : Résistance aux chocs196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each
Résistance environnementale : Température ambiante0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Sortie du jugement (HI, GO, LO) : Opération de sortieOpened at output operation
Résistance environnementale : Résistance aux vibrations10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each
Sortie de jugement (HI, GO, LO) : Protection contre les courts-circuitsIncorporated

Description du produit

High performance analog laser high resolution controller, HL-C2 series, RS232 port, analog output ±5V/ 4 - 20mA, PNP digital output
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top