Heures de service : Lundi à vendredi 9h00-18h00
ULSH201C5 - ULSH201C5 LS-H201-C5 PANASONIC Sensor head, diffuse reflective, range 300mm, cable 5m
En stock Produit phare

ULSH201C5

ULSH201C5 LS-H201-C5 PANASONIC Sensor head, diffuse reflective, range 300mm, cable 5m

$0.00USD
4941 en stock
Spécifications clés
Article:Specifications
Câble:0.09 mm22-core two parallel shielded cables, 2 m 6.562 ft long(Note:Cable cannot be extended.)
Détails:Sensor heads(Coaxial reflective type)
Produit:Amplifier-separated Type Digital Laser Sensor
Informations sur le fournisseur
PANASONIC
PANASONIC
Produits : 4316
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
ArticleSpecifications
Câble0.09 mm22-core two parallel shielded cables, 2 m 6.562 ft long(Note:Cable cannot be extended.)
DétailsSensor heads(Coaxial reflective type)
ProduitAmplifier-separated Type Digital Laser Sensor
MatérielEnclosure: PBTIndicator cover: PolycarbonateBeam-emitting / receiving surfaces: Glass
AccessoireMS-LS-1 (Mounting bracket): 1pc.
taille du spotApprox. dia. 2 mm dia. 0.079 in or less (at a distance from the sensor head of 300 mm 11.811 in)
ProtectionIP40 (IEC)
Numéro de pièceLS-H201-C5
Nom du produitAmplifier-separated Type Digital Laser Sensor LS-500
Numéro de produitLS-H201-C5
Objet de détectionOpaque, translucent, or transparent object(Note:Make sure to confirm detection with an actual sensor before use.)
Humidité ambiante35 to 85 % RH, Storage: 35 to 85 % RH
résistance aux chocs98 m / s2acceleration (10 G approx.) in X, Y and Z directions three times each
Portée de détection : HYPR750mm29.528 in(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Portée de détection : U-LG600mm23.622 in(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Éclairage ambiantIncandescent light: 3,000 ℓx or less at the light-receiving face
Température ambiante-10 to +55degrees + 14 to + 131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70degrees -4 to +158 degrees Fahrenheit
Indicateur de fonctionnementOrange LED (lights up when the amplifier output is ON)
résistance aux vibrations10 to 500 Hz frequency, 1.5 mm double amplitude or maximum acceleration 98 m/s2in X, Y, and Z direction for 2 hours each.
Amplificateurs compatiblesLS-501(P), LS-501(P)-C2(Note:When using the thru-beam typeLS-H101□orLS-H102□, do not set the receiving light sensitivity (gctL) of the applicableLS-500series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.)
Élément émetteur : TypeRed semiconductor laser diode
résistance d'isolation20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Conformité réglementaireEMC Directive, RoHS Directive
Portée de détection : mode standard300mm11.811 in(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Portée de détection : mode RAPIDE200mm7.874 in(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Portée de détection : mode H-SP150mm5.906 in(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Portée de détection : mode U-LG450mm17.717 in(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
tenue en tension1,000 V AC for one min. between all supply terminals connected together and enclosure
Élément émetteur : classe LaserClass 1 [IEC / EN / JIS / GB / KS / FDA](Note:This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
Élément émetteur : Puissance de sortie maximale2mW
Élément émetteur : longueur d'onde d'émission maximale660 nm 0.026 mil

Description du produit

LS500. Sensor head, diffuse reflection, range 750mm, cable 5m
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top