| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Câble | 0.2 mm24-core (emitter: 3-core) oil resistant cabtyre cable, 2 m6.562 ftlong |
| Sortir | PNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less (between output and +V)- Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) |
| Poids | Emitter: 50 g approx.Receiver: 50 g approx. |
| Détails | PNP output |
| Produit | Compact Size Picking Sensor |
| Matériel | Enclosure: Heat-resistant ABSLens cover: AcrylicIndicator cover: Acrylic |
| Pas de poutre | 24.6 mm 0.969 in |
| Protection | IP62 (IEC) |
| Numéro de pièce | NA1-PK3-PN |
| Nom du produit | Compact Size Picking Sensor NA1-PK3 |
| temps de réponse | 10 ms or less (when interference prevention function is used: 30 ms or less) |
| Portée de détection | 30 to 300 mm1.181 to 11.811 in(Note) The sensing range is the possible setting distance between the emitter and the receiver. |
| Numéro de produit | NA1-PK3-PN |
| Détection de la hauteur | 49.2 mm1.937 in |
| Objet de détection | ø29 mmø1.142 inor more opaque object(completely beam interrupted object) |
| Tension d'alimentation | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| rallonge de câble | Extension up to total 100 m328.084 ftis possible for both emitter and receiver with 0.3 mm2, or more, cable. |
| Humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Élément émetteur | Infrared LED (synchronized scanning system) |
| Degré de pollution | 3 (Industrial environment) |
| résistance aux chocs | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Indicateurs : Émetteur | Power indicator: Green LED (lights up when the power is ON)Job indicator: Orange LED (lights up when the job indicator input is High) |
| Éclairage ambiant | Incandescent light: 3,000 lx or less at the light-receiving face |
| Température ambiante | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed),Storage: -20 to +70 ℃-4 to +158 ℉ |
| Consommation de courant | Emitter: 30 mA or lessReceiver: 50 mA or less |
| Indicateurs : Récepteur | Operation indicator: Red LED (lights up when the output is ON)Stable incident beam indicator: Green LED (lights up when all beam channels are stably received)Job indicator: Orange LED (lights up when the job indicator input is High) |
| résistance aux vibrations | 10 to 150 Hz frequency, 0.75 mm0.030 in(5 G max.) double amplitude in X, Y and Z directions for two hours each |
| résistance d'isolation | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Nombre de canaux de faisceau | 3 beam channels |
| Sortie : Opération de sortie | ON or OFF when one or more beam channels are interrupted, selectable by operation mode switch |
| tenue en tension | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Résultat : Catégorie d'utilisation | DC-12 or DC-13 |
| Conformité à la directive de marquage CE | EMC Directive, RoHS Directive |
| Sortie : Protection contre les courts-circuits | Incorporated |
| Fonction de prévention des interférences | Incorporated (Up to 3 units can be mounted close together.) |