| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| PFHD | 3.73 × 10-9(Note) Probability of dangerous failure per hour. |
| Câble | 0.16 mm25-core heat-resistant PVC cable, 3 m 9.842 ft long |
| MTTFD | 100 years or more(Note) Mean time to dangerous failure. |
| Détails | Hand protection type Min. sensing object ø25 mmø0.984 in(20 mm0.787 inbeam pitch) |
| Produit | Ultra-slim Light Curtain [Type 2 PLc SIL1] |
| Matériel | Enclosure: Polycarbonate alloySensing surface: Polycarbonate alloyMS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) |
| Pas de poutre | 20 mm0.787 in |
| Accessoires | MS-SFC-1 (Standard mounting bracket): 1 setSF4C-TR25 (Test rod): 1 No. |
| Numéro de pièce | SF2C-H16-P |
| Nom du produit | Ultra-slim Light Curtain [Type2 PLc SIL1] SF2C |
| Tension d'alimentation | 24 V DC plus or minus 20 % Ripple P-P 10 % or less |
| temps de réponse | OFF response: 20 ms or lessON response: 80 to 100 ms |
| Numéro de produit | SF2C-H16-P |
| rallonge de câble | Extension up to total 50m is possible for 0.3mm2or more, cable |
| Plage de fonctionnement | 0.1 to 3 m0.328 to 9.843 ft |
| Élément émetteur | Infrared LED (Peak emission wavelength: 850 nm0.034 mil) |
| Degré de pollution | 3 |
| hauteur de protection | 320 mm12.598 in |
| Altitude opérationnelle | 2, 000 m6561.680 ftor less(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| Éclairage ambiant | Incandescent light: 5,000 ℓx or less at the light-receiving face |
| Sortie de verrouillage (SSD) | - Maximum sink current: 60mA- Applied voltage: same as supply voltage (between the lockout output and +V)- Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable)- Leakage current: 200micro A or less (power supply OFF condition)- Maximum load capacity: 2.2micro F (No load to maximum output current)- Load wiring resistance: 3Ω or less |
| Objet de détection min. | ø25 mmø0.984 inopaque object |
| Fonction de test d'entrée | Incorporated |
| Sortie de contrôle (OSSD) | - Maximum source current: 200mA- Applied voltage: same as supply voltage (between the control output and +V)- Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable)- Leakage current: 200micro A or less (power supply OFF condition)- Maximum load capacity: 2.2micro F (No load to maximum output current)- Load wiring resistance: 3Ω or less |
| Nombre de canaux de faisceau | 16 |
| angle d'ouverture effectif | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] |
| Normes applicables : Japon | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508-1 to 3 (SIL 1) |
| Normes applicables : Europe | EN 61496-1 (Type 2), EN ISO 13849-1:2015 (Category 2, PLc), EN 61508-1 to 3 (SIL 1), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
| Fonction de prévention des interférences | Incorporated |
| Normes applicables : Amérique du Nord | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark. |
| Sortie de verrouillage (SSD) : Mode de fonctionnement | ON during normal operation, OFF during lockout(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. |
| Sortie de contrôle (OSSD) : Mode de fonctionnement | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) |
| Fonction indicateur multifonctionnelle de grande taille | Incorporated |
| Sortie de verrouillage (SSD) : Circuit de protection | Incorporated |
| Sortie de commande (OSSD) : Circuit de protection | Incorporated |
| Réglementations et certifications applicables | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification |
| Résistance environnementale : humidité ambiante | 30 to 85 % RH, Storage: 30 to 85 % RH |
| Résistance environnementale : résistance aux chocs | 300 m / s2acceleration (30 G approx.) in X, Y and Z directions three times each |
| Poids net (total de l'émetteur et du récepteur) | 400 g approx. |
| Normes applicables : Norme internationale | IEC 61496-1 / 2 (Type 2), ISO 13849-1:2015 (Category 2, PLc), IEC 61508-1 to 3 (SIL 1) |
| Résistance environnementale : température ambiante | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: - 25 to +60 ℃- 13 to +140 ℉ |
| Résistance environnementale : Degré de protection | IP65, IP67 (IEC) |
| Résistance environnementale : résistance aux vibrations | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Résistance environnementale : résistance à l'isolation | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Résistance environnementale : tenue en tension | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |
| Consommation de courant : Un grand voyant multifonction s'allume | Emitter: 40 mA or lessReceiver: 35 mA or less |
| Consommation de courant : Voyants multifonctions éteints | Emitter: 30 mA or lessReceiver: 30 mA or less |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation