| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| PFHD | 1.90 × 10-9 |
| Câble | 0.15mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m16.404 ftlong |
| MTTFD | 100 years or more |
| Détails | Min. sensing object ø25 mmø0.984 intype (20 mm0.787 inbeam pitch) [Cable type] |
| Produit | Ultra-slim Safety Light Curtain [Type 4 PLe SIL3] |
| Matériel | Enclosure: Polycarbonate alloySensing surface: Polycarbonate alloy |
| Pas de poutre | 20 mm0.787 in |
| Accessoires | MS-SFC-1 (Standard mounting bracket): 1 setSF4C-TR25 (Test rod): 1 No. |
| Numéro de pièce | SF4C-H12 |
| Nom du produit | Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C |
| Fonction ELCA | Incorporated (reducing mutual interference automatically) |
| Tension d'alimentation | 24 V DC +10-15 % Ripple P-P 10 % or less |
| temps de réponse | OFF response: 7 ms or lessON response: 90 ms or less |
| Numéro de produit | SF4C-H12 |
| rallonge de câble | Extension up to 40.5 m132.874 ftis possible for both emitter and receiver, with 0.2 mm2or more cable.(Note) When the muting lamp is used, the cable can be extended within 30.5 m100.066 ft(for emitter / receiver). |
| Fonction de mise en sourdine | Incorporated |
| Plage de fonctionnement | 0.1 to 3 m0.328 to 9.843 ft(Note) The operating range is the possible setting distance between the emitter and the receiver. |
| Élément émetteur | Infrared LED (Peak emission wavelength: 855 nm0.034 mil) |
| Degré de pollution | 3 |
| Fonction de remplacement | Incorporated |
| hauteur de protection | 240 mm9.449 in |
| Fonction d'interverrouillage | Incorporated [Manual reset / Automatic reset (Note)](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status. |
| Altitude opérationnelle | 2,000 m6,561 68 ftor less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.) |
| Fonctions optionnelles | Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting(Note) In case of using optional function, the handy-controller SFC-HC is required. |
| Éclairage ambiant | Incandescent light: 5,000 lx or less at the light-receiving face |
| Objet de détection min. | ø25 mmø0.984 inopaque object(Note) When the floating blanking function is used, the size of the min. sensing object is changed. |
| Nombre de canaux de faisceau | 12 |
| Fonction d'entrée de sécurité | Incorporated (safety contact) |
| angle d'ouverture effectif | plus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2)] |
| Normes applicables : Japon | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3(SIL3) |
| Normes applicables : Europe | EN 61496-1 (Type 4), EN ISO 13849-1:2015 (Category 4, PLe), EN 61508-1 to 3 (SIL 3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
| Fonction de test/réinitialisation de l'entrée | Incorporated |
| Sorties de contrôle (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 200 mA- Applied voltage: same as supply voltage (between the control output and +V)- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less[When selecting NPN output]- Max. sink current: 200 mA- Applied voltage: same as supply voltage (between the control output and 0 V)- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less |
| Normes applicables : Amérique du Nord | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark. |
| fonction de surveillance des périphériques externes | Incorporated |
| Sortie auxiliaire (sortie non sécurisée) | PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and +V)- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m32.808 ftlength cable)[When selecting NPN output]- Max. sink current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m32.808 ftlength cable) |
| Réglementations et certifications applicables | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification |
| Résistance environnementale : humidité ambiante | 30 to 85 % RH, Storage: 30 to 85 % RH |
| Résistance environnementale : résistance aux chocs | 300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each |
| Poids net (total de l'émetteur et du récepteur) | 700 g approx. |
| Normes applicables : Norme internationale | IEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL 3) |
| Résistance environnementale : température ambiante | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +60 ℃-13 to +140 ℉ |
| Résistance environnementale : Degré de protection | IP67 / IP65 (IEC) |
| Résistance environnementale : résistance aux vibrations | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Résistance environnementale : résistance à l'isolation | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Sorties de commande (OSSD 1, OSSD 2) : Mode de fonctionnement | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.(Note) In case the blanking function is valid, the operation mode is changed. |
| Sorties de commande (OSSD1, OSSD2) : Circuit de protection | Incorporated |
| Résistance environnementale : tenue en tension | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Sortie auxiliaire (sortie non sécurisée) : Mode de fonctionnement | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller). |
| Sortie auxiliaire (sortie non protégée) : circuit de protection | Incorporated |
| Consommation de courant : Un grand voyant multifonction s'allume | Emitter: 120 mA or lessReceiver: 140 mA or less |
| Consommation de courant : Voyants multifonctions éteints | Emitter: 70 mA or lessReceiver: 90 mA or less |
Spécifications techniques et données de performance