Heures de service : Lundi à vendredi 9h00-18h00
USF4CH24 - USF4CH24 SF4C-H24 PANASONIC Ultra-slim Safety Light Curtain Typ4 (PLe SIL3), Hand Protection, protective hei..
En stock Produit phare

USF4CH24

USF4CH24 SF4C-H24 PANASONIC Ultra-slim Safety Light Curtain Typ4 (PLe SIL3), Hand Protection, protective hei..

$0.00USD
4251 en stock
Spécifications clés
Article:Specifications
PFHD:2.54 × 10-9
Câble:0.15mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m16.404 ftlong
MTTFD:100 years or more
Informations sur le fournisseur
PANASONIC
PANASONIC
Produits : 4316
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
ArticleSpecifications
PFHD2.54 × 10-9
Câble0.15mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m16.404 ftlong
MTTFD100 years or more
DétailsMin. sensing object ø25 mmø0.984 intype (20 mm0.787 inbeam pitch) [Cable type]
ProduitUltra-slim Safety Light Curtain [Type 4 PLe SIL3]
MatérielEnclosure: Polycarbonate alloySensing surface: Polycarbonate alloy
Pas de poutre20 mm0.787 in
AccessoiresMS-SFC-1 (Standard mounting bracket): 1 setSF4C-TR25 (Test rod): 1 No.
Numéro de pièceSF4C-H24
Nom du produitUltra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C
Fonction ELCAIncorporated (reducing mutual interference automatically)
Tension d'alimentation24 V DC +10-15 % Ripple P-P 10 % or less
temps de réponseOFF response: 7 ms or lessON response: 90 ms or less
Numéro de produitSF4C-H24
rallonge de câbleExtension up to 40.5 m132.874 ftis possible for both emitter and receiver, with 0.2 mm2or more cable.(Note) When the muting lamp is used, the cable can be extended within 30.5 m100.066 ft(for emitter / receiver).
Fonction de mise en sourdineIncorporated
Plage de fonctionnement0.1 to 3 m0.328 to 9.843 ft(Note) The operating range is the possible setting distance between the emitter and the receiver.
Élément émetteurInfrared LED (Peak emission wavelength: 855 nm0.034 mil)
Degré de pollution3
Fonction de remplacementIncorporated
hauteur de protection480 mm18.898 in
Fonction d'interverrouillageIncorporated [Manual reset / Automatic reset (Note)](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Altitude opérationnelle2,000 m6,561 68 ftor less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
Fonctions optionnellesFixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting(Note) In case of using optional function, the handy-controller SFC-HC is required.
Éclairage ambiantIncandescent light: 5,000 lx or less at the light-receiving face
Objet de détection min.ø25 mmø0.984 inopaque object(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
Nombre de canaux de faisceau24
Fonction d'entrée de sécuritéIncorporated (safety contact)
angle d'ouverture effectifplus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2)]
Normes applicables : JaponJIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3(SIL3)
Normes applicables : EuropeEN 61496-1 (Type 4), EN ISO 13849-1:2015 (Category 4, PLe), EN 61508-1 to 3 (SIL 3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
Fonction de test/réinitialisation de l'entréeIncorporated
Sorties de contrôle (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 200 mA- Applied voltage: same as supply voltage (between the control output and +V)- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less[When selecting NPN output]- Max. sink current: 200 mA- Applied voltage: same as supply voltage (between the control output and 0 V)- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less
Normes applicables : Amérique du NordANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark.
fonction de surveillance des périphériques externesIncorporated
Sortie auxiliaire (sortie non sécurisée)PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and +V)- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m32.808 ftlength cable)[When selecting NPN output]- Max. sink current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m32.808 ftlength cable)
Réglementations et certifications applicablesCE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification
Résistance environnementale : humidité ambiante30 to 85 % RH, Storage: 30 to 85 % RH
Résistance environnementale : résistance aux chocs300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each
Poids net (total de l'émetteur et du récepteur)880 g approx.
Normes applicables : Norme internationaleIEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL 3)
Résistance environnementale : température ambiante-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +60 ℃-13 to +140 ℉
Résistance environnementale : Degré de protectionIP67 / IP65 (IEC)
Résistance environnementale : résistance aux vibrations10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each
Résistance environnementale : résistance à l'isolation20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Sorties de commande (OSSD 1, OSSD 2) : Mode de fonctionnementON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.(Note) In case the blanking function is valid, the operation mode is changed.
Sorties de commande (OSSD1, OSSD2) : Circuit de protectionIncorporated
Résistance environnementale : tenue en tension1,000 V AC for one min. between all supply terminals connected together and enclosure
Sortie auxiliaire (sortie non sécurisée) : Mode de fonctionnementOFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Sortie auxiliaire (sortie non protégée) : circuit de protectionIncorporated
Consommation de courant : Un grand voyant multifonction s'allumeEmitter: 120 mA or lessReceiver: 145 mA or less
Consommation de courant : Voyants multifonctions éteintsEmitter: 75 mA or lessReceiver: 95 mA or less

Description du produit

SF4C safety barrier category 4, Ple, SIL3, 0.1 to 3m, "hand" protection 20 mm between beams, 13mm thick, protected height 480mm, operating range 0.1 to 3m, cable 5m
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top