


| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| PFHD | 4.30×10-9 |
| MTTFD | 272 years or more |
| Remarque | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃+68 ℉.PFHD: Probability of Dangerous Failure per Hour, MTTFD: Mean Time to Dangerous Failure (in years). |
| Détails | Min. sensing object ø25 mmø0.984 in(20 mm0.787 inbeam pitch) |
| Produit | Safety Light Curtain [Type 4 PLe SIL3] |
| Matériel | Enclosure : Aluminum, Detection surface : Polycarbonate resin and stainless steel (SUS304), Upper cap / lower cap : Nylon |
| Accessoires | SF4B-TR25 (test rod) : 1 pc. |
| Numéro de pièce | SF4D-H96 |
| Nom du produit | Compact & Robust Safety Light Curtain [Type 4 PLe SIL3] SF4D |
| État de sécurité | Control output (OSSD 1 / 2) OFF state |
| Tension d'alimentation | 24 V DC+20-30 %Ripple P-P 10 % or less (excluding voltage drop due to cable)(Note): In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline. |
| Numéro de produit | SF4D-H96 |
| Type de sous-système | Type B (IEC 61508-2) |
| rallonge de câble | Total length of emitter / receiver can be extended up to 70 m229.659 fteach using optional mating cable (including the lengthof series mating cables)(Note): In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline. |
| Fonction de mise en sourdine | Incorporated (12-core cable) |
| Plage de fonctionnement | Short mode : 0.2 to 9 m0.656 to 29.528 ftLong mode : 0.8 to 15 m2.625 to 49.213 ft(selectable by DIP switch)(Note): The operating range is the possible setting distance between the emitter and the receiver. |
| Élément émetteur | Infrared LED (peak emission wavelength : 850 nm0.0335 mil) |
| Degré de pollution | 3 |
| Méthode de connexion | By connector |
| Fonction de remplacement | Incorporated (12-core cable) |
| hauteur de protection | 1,910 mm75.197 in(Note): When using as a safety device for a press machine in China, the length from the center of the first beam channel to the center of the last beam channel become to be protective height. |
| Fonction d'interverrouillage | Incorporated [Manual reset / auto reset (selectable by wiring)] (8-core cable or 12-core cable) |
| Altitude opérationnelle | 2,000 m6,561.68 ftor less(Note): Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| Fonctions optionnelles | Fixed blanking function, floating blanking function, interlock setting function, external device monitoring setting function, auxiliary output settingfunction, application indicator setting function, muting setting function, override setting function, protect function, cable switching function(Note): To use optional functions, the SF4D-TM1 (optional) and Configurator Light Curtain setting software are required. |
| Éclairage ambiant | Incandescent light : 5,000 ℓx or less at the light-receiving surface |
| Consommation de courant | Emitter : 120 mA or lessReceiver : 160 mA or less |
| Objet de détection min. | ø25 mmø0.984 inopaque object(Note): When the floating blanking function is used, the size of the minimum sensing object varies. For the detail, refer to the section on Safety distance. |
| fonction d'économie d'énergie | Incorporated |
| Fonction de test d'entrée | Incorporated |
| Nombre de canaux de faisceau | 96 |
| temps de réponse en cas de panne | Within response time (OFF response) |
| Méthode de synchronisation | Line synchronization / optical synchronization (selectable by DIP switch) |
| angle d'ouverture effectif | ±2.5° or less at a sensing range of 3 m9.843 ftor longer (based on IEC 61496-2) |
| fonction de déverrouillage | Incorporated |
| T1 (intervalle de test de preuve) | 20 years |
| Normes applicables : Chine | GB/T 4584 |
| Normes applicables : Japon | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3 (SIL3) |
| Normes applicables : Europe | EN ISO 13849-1:2015 (Category 4, PLe), EN 55011, EN 61000-6-2, EN IEC 63000 |
| SFF (fraction de défaillance sûre) | 99% |
| Fonction d'indicateur d'application | Incorporated (only the receiver lights up when optical synchronization is used) |
| TFT (Tolérance aux pannes matérielles) | 1 |
| Sorties de contrôle (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open collector transistor (selectable)<PNP output selected>・Maximum source current : 350 mA・Applied voltage : Same as supply voltage(between control output and +V)・Residual voltage : 2 V or less (source current 350 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)・Maximum load capacity : 2.2 μF・Load wiring resistance : 3 Ω or less<NPN output selected>・Maximum sink current : 350 mA・Applied voltage : Same as supply voltage(between control output and 0 V)・Residual voltage : 2 V or less (sink current 350 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)・Maximum load capacity : 2.2 μF・Load wiring resistance : 3 Ω or less |
| Fonction de prévention des interférences | <Not connected in series/parallel>・Line synchronization : 2 units or less (auto)・Optical synchronization : 2 units or less (selectable by DIP switch)<Connected in series/parallel>・Series connection : 5 units or less (total number of beam channels 256 or less)・Parallel connection : 3 units or less (total number of beam channels 192 or less)(Note)・Series / parallel connection mixed : 5 units or less (total number of beam channels 144 or less)(Note)(Note): The setting can be changed when the SF4D-TM1 (optional) and Configurator Light Curtain setting software are used. |
| Normes applicables : Amérique du Nord | ANSI/UL 61496-1/2 (Type 4),CAN/CSA C22.2 No.14, CAN/CSA E61496-1/2 |
| fonction de surveillance des périphériques externes | Incorporated (8-core cable or 12-core cable) |
| Poids (total de l'émetteur et du récepteur) | 4,800g approx. |
| Réglementations et certifications applicables | CE Marking (Machinery Directive, EMC Directive, RoHS Directive) , UKCA Marking (Machinery Regulations, EMC Regulations, RoHS Regulations), TÜV SÜD certification (U.S.A., Canada), OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06, Korea KCs mark |
| Sortie auxiliaire (AUX) (Sortie non sécurisée) | PNP open-collector transistor / NPN open collector transistor (selectable)<PNP output selected>・Maximum source current : 60 mA・Applied voltage : Same as supply voltage(between auxiliary output and +V)・Residual voltage : 2 V or less (source current 60 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)<NPN output selected>・Maximum sink current : 60 mA・Applied voltage : Same as supply voltage(between auxiliary output and 0 V)・Residual voltage : 2 V or less (sink current 60 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state) |
| Résistance environnementale : humidité ambiante | 30 to 85 % RH, Storage : 30 to 95 % RH |
| Résistance environnementale : résistance aux chocs | 300 m/s2acceleration (30 G approx.) in X, Y, and Z directions three times eachMalfunction resistance 100 m/s2acceleration (10 G approx.) in X, Y, and Z directions 1,000 times each |
| Normes applicables : Norme internationale | IEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3) |
| Sortie de contrôle (OSSD 1, OSSD 2) : Temps de réponse | OFF response : 10 ms or less (Not connected in series / parallel), 18 ms or less (Connected in series / parallel)(Note 1)ON response : 50 ms or less (Note 2)(Note 3)(Note 1): For response times by number of beams, refer to the Control output (OSSD 1, OSSD 2) OFF response times.(Note 2): Because the control output (OSSD 1, OSSD 2) must be OFF for at least 80 ms, the ON response will be delayed more than 50 ms when the light blocked time is less than 30 ms.(Note 3): When optical synchronization is selected, if the beam axes of both the top end and bottom end are blocked, the ON response speed decreases by as much as 1 sec. |
| Résistance environnementale : température ambiante | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage : -25 to +60 ℃-13 to +140 ℉ |
| Résistance environnementale : Degré de protection | IP67, IP65 (IEC), NEMA Type 13 (NEMA 250) |
| Résistance environnementale : résistance aux vibrations | 10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions for two hours eachMalfunction resistance 10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions twenty times each |
| Résistance environnementale : résistance à l'isolation | 20 MΩ, or more, with 500 V DC megger, between all supply terminals connected together and enclosure |
| Sorties de commande (OSSD 1, OSSD 2) : Mode de fonctionnement | ON when all beams are received, OFF when one or more beams are blocked(Also OFF when internal sensor error or synchronization signal error occurs)(Note): The setting can be changed when the SF4D-TM1 (optional) and Configurator Light Curtain setting software are used. |
| Sorties de commande (OSSD1, OSSD2) : Circuit de protection | Incorporated |
| Résistance environnementale : tenue en tension | 1,000 V AC for one minute, between all supply terminals connected together and enclosure |
| Sortie auxiliaire (AUX) (Sortie non sécurisée) : Temps de réponse | OFF response : 60 ms or less, ON response : 60 ms or less |
| Sortie auxiliaire (AUX) (Sortie non sécurisée) : Mode de fonctionnement | Control output ON : OFF, Control output OFF : ON(Note): The setting can be changed when the SF4D-TM1 (optional) and Configurator Light Curtain setting software are used. |
| Sortie auxiliaire (AUX) (sortie non protégée) : circuit de protection | Incorporated |
| Hauteur de protection : Lors de l'utilisation comme équipement de sécurité pour les presses chinoises | 1,900 mm74.803 in(Note): When using as a safety device for a press machine in China, the length from the center of the first beam channel to the center of the last beam channel become to be protective height. |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation