| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Poids | Net weight: 320 g approx. |
| Détails | Connector connection type control unit |
| Produit | Exclusive Control Unit for Safety Light Curtain |
| Calibre du fusible | Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down |
| Numéro de pièce | SF-C11 |
| Nom du produit | Exclusive Control Unit for Safety Light Curtain SF-C10 |
| Tension d'alimentation | 24 V DC ±10 % Ripple P-P 10 % or less / 100 mA or less (without safety light curtain) |
| temps de réponse | 10 ms or less |
| Sortie de sécurité | NO contact × 3 (13-14, 23-24, 33-34) |
| Numéro de produit | SF-C11 |
| Humidité ambiante | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Degré de pollution | 2 |
| Sorties auxiliaires | Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path) |
| Matériau d'enveloppe | ABS |
| Température ambiante | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉ |
| Terminal de connexion | Detachable spring-cage terminal |
| Consommation de courant | 100 mA or less (without light curtain) |
| Catégorie de surtension | II |
| résistance aux vibrations | Resistance / malfunction 10 to 55 Hz frequency, 0.35 mm0.014 inamplitudein X, Y, and Z directions for twenty times each |
| fonction de bord de fuite | Incorporated |
| Indicateurs : Défaut (DÉFAUT) | Yellow LED (blinks when fault occurs) |
| Normes applicables : Japon | JIS B 9704-1 (Type 4), JIS B 9705-1(Category 4), |
| fonction de sélection de polarité | Incorporated (Sliding switch allows selection of plus/minus ground)Minus ground: Correspond to PNP output safety light curtainPlus ground: Correspond to NPN output safety light curtain(Note:Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.) |
| Indicateurs : Alimentation (Ui) | Green LED (lights up when the power is ON) |
| Indicateurs : Sortie de sécurité [OUT] | Green LED (lights up when safety output is closed)(Note:The operation indicator is marked as "Enabling" on the unit forSF-C12.) |
| Conformité à la directive de marquage CE | Machinery Directive, Low Voltage (SF-C11/C13 only) Directive, EMC Directive, RoHS Directive |
| fonction de surveillance du relais externe | Incorporated |
| Normes applicables : Europe (UE) | EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), ISO 13849-1 (Category 4, PLe) |
| Sortie de sécurité : résistance de contact | 100 mOhm or less (initial value) |
| Barrières immatérielles de sécurité connectables | SF4D / SF4B / SF4B-G / SF2Bseries |
| Indicateurs : Verrouillage (INTER_LOCK) | Yellow LED (lights up when safety output is opened) |
| Sécurité de sortie : Durée de vie électrique | 100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
| Sécurité de fonctionnement : Durée de vie mécanique | 10,000,000 times or more (open/close frequency of 180 times/min)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
| Normes applicables : Amérique du Nord | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) (Note:SF-C11andSF-C13comply with UL 1998 (Class 2).) |
| Sortie de sécurité : Catégorie d'application | AC-15, DC-13 (IEC 60947-5-1) |
| Sortie auxiliaire à semi-conducteurs (AUX) | <Minus ground (Setting for PNP)>PNP open-collector transistor・Max. source current: 60 mA・Applied voltage: sameas supply voltage(between the semiconductor auxiliary output and +V)・Residual voltage: 2.3 V or less (at source current 60 mA)Leakage current: 2 mA or less<Plus ground (Setting for NPN)>NPN open-collector transistor・Max. sink current: 60 mA・Applied voltage: same as supply voltage(between the semiconductorauxiliary output and 0 V)・Residual voltage: 1.5 V or less(at sink current 60 mA)Leakage current: 2 mA or less |
| Délai de prise en charge (Réinitialisation automatique / Réinitialisation manuelle) | 80 ms or less / 90 ms or less |
| Sortie de sécurité : Matériau de contact / contacts | AgSnO, self cleaning, positively driven |
| Normes applicables : Norme internationale | IEC 61496-1 (Type 4) |
| Sortie de sécurité : fusible de protection des contacts calibré | 6 A (slow blow) |
| Résistance environnementale : Degré de protection | Enclosure: IP40Terminal: IP20 |
| Sortie auxiliaire : fusible de protection des contacts calibré | 2 A (slow blow) |
| Sortie auxiliaire : tension/courant de fonctionnement nominal | 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) |
| Sortie auxiliaire à semi-conducteurs (AUX) : Fonctionnement de la sortie | Related to auxiliary output of safety light curtain |
| Sortie de sécurité : tension de fonctionnement nominale (Ue) / courant de fonctionnement nominal (le) | 6 A / 30 V DC, 6 A / 230 V AC, resistive load (For inductive load, during contact protection) Min. applicable load: 10 mA (at 24 V DC)(Note:If severalSF-C11orSF-C13units are being used in a line together, leavea space of 5 mm0.197 inor more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs below.) |
Spécifications techniques et données de performance