| Paramètre | Valeur |
|---|---|
| Ue | |
| DC | Resistive load (DC-12) |
| c'est-à-dire | Main circuit, look monitor circuit |
| B10D | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| Article | Specifications |
| Câble | UL style 2464, No.22 AWG 12-core |
| Poids | Approx. 600 g |
| Détails | Spring lock type |
| Produit | Ultra-slim Safety door switch with solenoid interlock |
| Matériel | Enclosure : PA66 |
| Protection | IP 67 (IEC 60529) |
| Numéro de pièce | SG-B1-SA-G5 |
| longueur du câble | 5m16.404 ft |
| Nom du produit | Ultra-slim Safety door switch with solenoid interlock SG-B1 |
| Principaux contacts | 1NC + 1NC |
| Numéro de produit | SG-B1-SA-G5 |
| Force d'interverrouillage | 500 N min. (GS-ET-19)(Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value.Do not apply a load higher than the rated value.When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| résistance aux chocs | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| résistance de contact | 300 mΩ max. (initial value, 1 m3.281 ftcable)700 mΩ max. (initial value, 5 m16.404 ftcable) |
| Fréquence de fonctionnement | 900 operations/hour |
| Normes applicables | EN 60947-5-1, GS-ET-19 |
| force d'ouverture directe | 60 N min. |
| circuit de surveillance de porte | AC |
| résistance aux vibrations | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| voyage d'ouverture directe | 8 mm0.315 inmin. |
| contacts de surveillance de porte | 2NC |
| durabilité électrique | 100,000 operations min.(900 operations/hour,AC-12 125 V 2A, DC-12 125 V 0.4 A)1,000,000 operations min.(900 operations/hour,24 V AC/DC 0.1 A resistive load) |
| Verrouiller les contacts de surveillance | 1NC |
| durabilité mécanique | 1,000,000 operations min. (GS-ET-19) |
| Courant thermique (Ith) | ・Ambient temperature : -25 to +35 ℃-13 to +95 ℉2.5 A (up to 2 circuits)1.0 A (3 or more circuits)・Ambient temperature : 35 to +50 ℃95 to +122 ℉1.0 A (1 circuit)0.5 A (2 or more circuits) |
| Réglementation applicable | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] |
| Charge inductive (AC-15) | - |
| Charge inductive (DC-13) | 1A |
| vitesse de fonctionnement de l'actionneur | 0.05 to 1.0 m/sec. |
| Tension d'isolation nominale (Ui) | 300 V (Door monitor circuit)150 V (Main, Lock monitor circuit)30 V (Between ground and LED, solenoid circuit) |
| Conditions de fonctionnement : Altitude | 2,000 m6,561.68 ftmax. |
| classe de protection contre les chocs électriques | Class II (IEC 61140)(Note), 回(double insulated)(Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| Dispositif de protection contre les courts-circuits | Use 250 V / 10 A fast acting type fuse |
| Tension de tenue aux impulsions (Uimp) | 2.5 kV (Door monitor circuit)1.5 kV (Main, Lock monitor circuit)0.5 kV (Between ground and LED, solenoid circuit) |
| Électrovanne / Indicateur : Indicateur | Green LED |
| Électrovanne / Indicateur : Courant nominal | 110 mA (solenoid 100 mA, LED 10 mA : initial value) |
| Conditions de fonctionnement : humidité ambiante | 45 to 85 % RH |
| Conditions de fonctionnement : degré de pollution | 3 (Inside 2) |
| Solénoïde / Indicateur : Tension de mise sous tension | Rated voltage × 85 % max. (at 20 ℃68 ℉) |
| Électrovanne / Indicateur : Couper la tension | Rated voltage × 10 % min. (at 20 ℃68 ℉) |
| Normes applicables : Normes d'utilisation | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 |
| Conditions de fonctionnement : Température ambiante | -25 to +50 ℃-13 to +122 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| Électrovanne / Indicateur : Tension de fonctionnement nominale | DC 24 V 100% duty cycle |
| Tension de fonctionnement nominale (Ue) / Courant de fonctionnement nominal (Ie) | Ue30V125V250VIeMain circuit, look monitor circuitACResistive load (AC-12)-2A-Inductive load (AC-15)-1A-DCResistive load (DC-12)2A0.4A-Inductive load (DC-13)1A0.22A-Door monitor circuitACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |