Spécifications clés
Article:Specifications
Câble:4–core cabtyre cable, 3 m9.843 ftlong
Remarque:Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃+73 ℉.■Transponder specificationsOperating frequency: 125 kHzMax. transmitter output: 3.33 μW
Poids:Switch body (sub): 110 g approx., Actuator: 10 g approx.
Informations sur le fournisseur
PANASONIC
PANASONIC
Produits : 4316
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
ArticleSpecifications
Câble4–core cabtyre cable, 3 m9.843 ftlong
RemarqueWhere measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃+73 ℉.■Transponder specificationsOperating frequency: 125 kHzMax. transmitter output: 3.33 μW
PoidsSwitch body (sub): 110 g approx., Actuator: 10 g approx.
DétailsCompact type(High code / Sub)
ProduitNon-Contact Safety Door Switch
MatérielSwitch body: PBT, PC, SUS (stainless steel), EPDMActuator: PBT
Numéro de pièceSG-P2010-S
Poids brut190 g approx.
Nom du produitNon-Contact Safety Door Switch SG-P
Tension d'alimentation24V DC+10-20% Ripple P-P 10 % or less
temps de réponse• For single unit: ON→OFF 100 ms or less, OFF→ON 100 ms or less• For multiple units: Time for single unit + 5 ms x (number of connected units - 1)
Numéro de produitSG-P2010-S
Degré de pollution3
Consommation de courant20 mA or less
Vérifier l'entrée et la sortieDedicated communication line between the switch body (standard) and the switch body (sub) (Note)* It is not for external input and output. (voltage range 0 V to 5 V DC)(Note) : When using the device as a single unit, connect the check input with the check output.
Longueur du câble connecté• When using only one unit: Maximum cable length of 20 m 65.617 ft between switch body and power supply unit• When connecting multiple units in series: Maximum total cable length of 100 m328.084 ft, maximum cable length of 20 m65.617 ftbetween two adjacent units
Normes applicables : JaponJIS B 9705-1, JIS C 0508-1 to 3 (SIL3), JIS B 9961, JIS C 8201-5-2, JIS B 9710
Normes applicables : EuropeEN ISO 13849-1 : 2015 (Category 4, PLe), EN ISO 14119, EN 60947-5-3, EN 300 330, EN IEC 63000, EN 301 489-1
Sorties de contrôle (OSSD 1, OSSD 2)
Distance de fonctionnement : Avant / CôtéSao (OFF→ON): 5 mm0.197 in, Sar (ON → OFF): 15 mm0.591 in
Normes applicables : Amérique du NordCAN/CSA C22.2 No.14, UL508
Nombre d'unités connectées en série30 units or less (standard 1 unit, sub 29 units)
Sortie de commande (OSSD) : Circuit de protection
Réglementations et certifications applicablesCE Marking (Machinery Directive, RE Directive, RoHS Directive), UKCA Marking (Supply of Machinery (Safety) Regulations, RE Regulations, RoHS Regulations), TÜV SÜD certification, TÜV SÜD certification (U.S.A., Canada), the U.S.'s radio regulations (FCC) (Note), Canada's radio regulations (ICES-003, RSS-310) (Note), Singapore's radio regulations (IMDA certification) (Note), Thailand's radio regulations (NBTC certification) (Note), Philippines' radio regulations (NTC certification) (Note), Korea's radio regulations (KC certification) (Note), India's radio regulations (WPC certification) (Note), Indonesia's radio regulations (SDPPI certification) (Note), Malaysia's radio regulations (SIRIM certification) (Note)(Note) : This product uses a weak radio signal for its detection operation. Please confirm compliance with applicable laws in the country of use.
Résistance environnementale : humidité ambiante30 to 85 % RH, storage: 30 to 95 % RH
Résistance environnementale : résistance aux chocs300 m/s2(approx. 30 G), 3 times each in X, Y, and Z direction
Normes applicables : Norme internationaleISO 13849-1 : 2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), IEC 60947-5-3, ISO 14119
Résistance environnementale : température ambiante-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +65 ℃-13 to +149 ℉
Résistance environnementale : Degré de protectionIP65(IEC)
Résistance environnementale : résistance aux vibrations10 to 55Hz, 1 mm double amplitude, 2 hours each in X, Y, and Z directions
Résistance environnementale : résistance à l'isolation20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
Sorties de commande (OSSD 1, OSSD 2) : Mode de fonctionnement
Résistance environnementale : tenue en tension1,000 V AC for one minute between all supply terminals connected together and enclosure

Description du produit

SG-P2010-S_Non-Contact Safety Door Switch_Non-Contact Safety Door Switch SG-P_Compact type(High code / Sub)
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top