| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Câble | Shielded cable with connector, 1 m3.281 ftlong |
| Détails | Sensor head |
| Produit | Compact Type 4 Safety Beam Sensor |
| Matériel | Enclosure: PBT (Polybutylene terephthalate)Lens: AcrylicIndicator cover: Acrylic |
| Numéro de pièce | ST4-A1-J1V |
| Nom du produit | Compact Type 4 Safety Beam Sensor ST4 |
| Tension d'alimentation | Supplied from controller |
| Numéro de produit | ST4-A1-J1V |
| Objet de détection | φ9 mmφ0.354 inor more opaque object |
| rallonge de câble | Extention up to total 50 m164.042 ftis possible for both emitter and receiver with exclusive cable. |
| Plage de fonctionnement | 0.1 to 15 m0.328 to 49.213 ft(Note:The operating range is the possible setting distance between the emitter and the receiver. It can detect sensing object of less than 0.1 m 0.328 ft away.) |
| Élément émetteur | Infrared LED (Peak emission wavelength: 870 nm0.034 mil) |
| Éclairage ambiant | Incandescent lamp: 3,500 Lx or less at the light-receiving face |
| Consommation de courant | Emitter: 11 mA or lessReceiver: 9 mA or less |
| Normes applicables | IEC 61496-1/2 (JIS B 9704-1/2 / UL 61496-1/2) (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9705-1 (Category 4), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), JIS C 0508-1 to 3 (SIL3), UL 1998, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI/RIA R15.06, ANSI/ISA S84.01 (SIL3)(Note) Complies with those standards only when the sensor head is used in combination with the controller ST4-C11 / ST4-C12EX. |
| Indicateur d'émission de faisceau | Green LED (lights up during beam emission, lights off during emission halt) |
| angle d'ouverture effectif | plus or minus 2.5degrees or less for operating range exceeding 3 m 9.843 ft (required by IEC 61496-2 / UL 61496-2) |
| Indicateur d'interruption de faisceau | Red LED (lights up when the beam is interrupted or lock out, lights off during reception)(Note) Shows light interruption information between the emitter and the receiver with the same address. It does not show OSSD output. |
| Indicateur de faisceau incident stable | Green LED (lights up under stable light received condition, lights off under unstable light received condition) |
| Conformité à la directive de marquage CE | Machinery Directive, EMC Directive, RoHS Directive |
| Poids (total de l'émetteur et du récepteur) | Net weight: 100 g approx.Gross weight: 140 g approx. |
| Résistance environnementale : humidité ambiante | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Résistance environnementale : résistance aux chocs | 300 m/s2acceleration in X, Y and Z directions three times each |
| Résistance environnementale : température ambiante | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉ |
| Résistance environnementale : Degré de protection | IP67 (IEC) |
| Résistance environnementale : résistance aux vibrations | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 90 m/s2 in X, Y and Z directions for two hours each< |
| Résistance environnementale : résistance à l'isolation | 20 MOhm or more with 500V DC megger between all supply terminals connected together and enclosure |
| Résistance environnementale : tenue en tension | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation