Spécifications clés
1 631 (F3SJ-A____P14/P30):180
Modèle (F3SJ-A____P14/P30):Protected height (mm)
Matériel (F3SJ-A____P14/P30):Casing (including metal parts on both ends): Aluminum, zinc die-castCap: ABS resin, Optical cover: PMMA resin (acrylic), Cable: Oil resistant PVC
Récepteur (F3SJ-A____P14/P30):Light intensity level indicators (green LED × 2, orange LED × 3): ON based on the light intensityError mode indicators (red LED × 3): Blink to indicate error detailsOFF output indicator (red LED × 1): ON when safety output is OFF, blinks at lockout.ON output indicator (green LED × 1): ON while safety output is ONMuting error indicator, Blanking/test indicator (green LED × 2): ON/flash according to function
Informations sur le fournisseur
OMRON
OMRON
Produits : 41472
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
1 631 (F3SJ-A____P14/P30)180
Modèle (F3SJ-A____P14/P30)Protected height (mm)
Matériel (F3SJ-A____P14/P30)Casing (including metal parts on both ends): Aluminum, zinc die-castCap: ABS resin, Optical cover: PMMA resin (acrylic), Cable: Oil resistant PVC
Récepteur (F3SJ-A____P14/P30)Light intensity level indicators (green LED × 2, orange LED × 3): ON based on the light intensityError mode indicators (red LED × 3): Blink to indicate error detailsOFF output indicator (red LED × 1): ON when safety output is OFF, blinks at lockout.ON output indicator (green LED × 1): ON while safety output is ONMuting error indicator, Blanking/test indicator (green LED × 2): ON/flash according to function
Condition (F3SJ-A____P14/P30)1 set
Indicateur (F3SJ-A____P14/P30)Emitter
281 à 389 (F3SJ-A____P14/P30)30 to 42
407 à 497 (F3SJ-A____P14/P30)44 to 54
420 à 720 (F3SJ-A____P14/P30)17 to 29
515 à 605 (F3SJ-A____P14/P30)56 to 66
623 à 731 (F3SJ-A____P14/P30)68 to 80
767 à 983 (F3SJ-A____P14/P30)84 to 108
Accessoires (F3SJ-A____P14/P30)Test rod (*1), instruction manual, standard mounting bracket (F39-LJ1 bracket for top/bottom mounting), mounting brackets (intermediate) (*2), error mode label, User's Manual (CD-ROM)*1. The F3SJ-A☐☐☐☐55 is not included.*2. Number of intermediate brackets depends on protective height of F3SJ.For protective height from 600 to 1,130 mm : 1 set for each of the emitter and receiver is includedFor protective height from 1,136 to 1,658 mm: 2 sets for each of the emitter and receiver are includedFor protective height from 1,660 to 2,180 mm : 3 sets for each of the emitter and receiver are includedFor protective height from 2,195 to 2,500 mm : 4 sets for each of the emitter and receiver are included
745 à 1 045 (F3SJ-A____P14/P30)30 to 42
Tension d'entrée (F3SJ-A____P14/P30)Test input, interlock selection input, reset input, and muting input are allON voltage: 9 to 24 V (Vs) (sink current: 3 mA max.), OFF voltage: 0 to 1.5 V, or openExternal device monitoring inputON voltage: 9 to 24 V (Vs) (sink current: 5 mA max.), OFF voltage: 0 to 1.5 V, or open
Fonction de test (F3SJ-A____P14/P30)Self test (at power-ON and at power distribution)External test (emission stop function by test input)
1 055 à 1 271 (F3SJ-A____P14/P30)116 to 140
1 070 à 1 295 (F3SJ-A____P14/P30)43 to 52
1 343 à 1 559 (F3SJ-A____P14/P30)148 to 172
1 395 à 1 620 (F3SJ-A____P14/P30)56 to 65
1 745 à 1 995 (F3SJ-A____P14/P30)70 to 80
2 120 à 2 495 (F3SJ-A____P14/P30)85 to 100
10 (Spécifications et informations de commande)245
12 (Spécifications et informations de commande)295
16 (Spécifications et informations de commande)395
19 (Spécifications et informations de commande)470
21 (Spécifications et informations de commande)520
22 (Spécifications et informations de commande)545
23 (Spécifications et informations de commande)570
25 (Spécifications et informations de commande)620
26 (Spécifications et informations de commande)245
28 (Spécifications et informations de commande)263
29 (Spécifications et informations de commande)720
32 (Spécifications et informations de commande)795
34 (Spécifications et informations de commande)317
35 (Spécifications et informations de commande)870
37 (Spécifications et informations de commande)920
38 (Spécifications et informations de commande)945
41 (Spécifications et informations de commande)1,020
42 (Spécifications et informations de commande)389
44 (Spécifications et informations de commande)1,095
45 (Spécifications et informations de commande)1,120
48 (Spécifications et informations de commande)1,195
50 (Spécifications et informations de commande)461
51 (Spécifications et informations de commande)1,270
56 (Spécifications et informations de commande)1,395
60 (Spécifications et informations de commande)551
65 (Spécifications et informations de commande)1,620
68 (Spécifications et informations de commande)623
70 (Spécifications et informations de commande)1,745
75 (Spécifications et informations de commande)1,870
76 (Spécifications et informations de commande)695
80 (Spécifications et informations de commande)1,995
88 (Spécifications et informations de commande)803
90 (Spécifications et informations de commande)2,245
95 (Spécifications et informations de commande)2,370
96 (Spécifications et informations de commande)875
100 (Spécifications et informations de commande)2,495
108 (Spécifications et informations de commande)983
116 (Spécifications et informations de commande)1,055
124 (Spécifications et informations de commande)1,127
132 (Spécifications et informations de commande)1,199
140 (Spécifications et informations de commande)1,271
Humidité ambiante (F3SJ-A____P14/P30)Operating: 35% to 85% (no condensation), Storage: 35% to 95%
Résistance aux chocs (F3SJ-A____P14/P30)Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions
Méthode de connexion (F3SJ-A____P14/P30)Connector method (M12, 8-pin)
Connexion en série (F3SJ-A____P14/P30)Time division emission by series connectionNumber of connections: up to 4 sets (F3SJ-A only) F3SJ-E, F3SJ-B and F3SJ-TS cannot be connected.Total number of beams: up to 400 beamsMaximum cable length for 2 sets: no longer than 15 m
Poids (emballé) (F3SJ-A____P14/P30)Calculate using the following expressions:(1) For F3SJ-A____14, weight (g) = (protective height) x 1.7 +α(2) F3SJ-A____30, weight (g) = (protective height) x 1.5 +αThe values forαare as follows:Protected height 245 to 596 mm: = 1,100 protected height 1,660 to 2,180 mm: = 2,400Protected height 600 to 1,130 mm: = 1,500 protected height 2,195 to 2,500 mm: = 2,600Protected height 1,136 to 1,658 mm: = 2,000
Tension de tenue (F3SJ-A____P14/P30)1,000 VAC 50/60 Hz, 1 min
Circuit de protection (F3SJ-A____P14/P30)Output short-circuit protection, and power supply reverse polarity protection
Température ambiante (F3SJ-A____P14/P30)Operating: -10 to 55°C (no icing), Storage: -30 to 70°C
Série F3SJ-A____14 (F3SJ-A____P14/P30)245 to 263
Série F3SJ-A____30 (F3SJ-A____P14/P30)245 to 395
Normes applicables (F3SJ-A____P14/P30)IEC 61496-1, EN 61496-1 UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment)IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices)IEC 61508-1 to -3, EN 61508-1 to -3 SIL3IEC 13849-1: 2006, EN ISO 13849-1: 2008 (PLe, Cat.4)UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
Degré de protection (F3SJ-A____P14/P30)IP65 (IEC 60529)
Résistance aux vibrations (F3SJ-A____P14/P30)Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions
résistance d'isolement (F3SJ-A____P14/P30)20 MΩ min. (at 500 VDC)
0,2 à 7 m (Spécifications et informations de commande)1,745 to 2,495
Application (Spécifications et informations de commande)Detection capability
Fonctions liées à la sécurité (F3SJ-A____P14/P30)Start interlock, restart interlock (Must be set with a setting tool when the muting function is used.)External device monitorMuting (Lamp burnout detection, override function included. F39-CN6 key cap for muting is required.)Fixed blanking (must be set by a setting tool)Floating blanking (must be set by a setting tool)
Lampe à incandescence non utilisée (F3SJ-A____P14/P30)100 m
Nombre de poutres (Spécifications et informations de commande)Protective height (mm)2
Protection des doigts (Spécifications et informations de commande)Dia. 14 mm
Protection des mains et des bras (Spécifications et informations de commande)Dia. 30 mm
Intensité lumineuse ambiante de fonctionnement (F3SJ-A____P14/P30)Incandescent lamp: receiving-surface light intensity of 3,000 lx max., Sunlight: receiving-surface light intensity of 10,000 lx max.
Fonction de prévention des interférences mutuelles (F3SJ-A____P14/P30)Interference light prevention algorithm, sensing distance change function
(Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))Laser pointer for F3SJ
Utilisation d'une lampe à incandescence pour la sortie d'indicateur externe 1 (F3SJ-A____P14/P30)60 m
Utilisation d'une lampe à incandescence pour la sortie d'indicateur externe 2 (F3SJ-A____P14/P30)40 m
7 m (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))F39-JD7A
10 m (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))F39-JD10A
15 m (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))F39-JD15A
20 m (Câble à connecteur unique (2 câbles par jeu, pour l'émetteur et le récepteur))F39-JD20A
Modèle (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))F3SJ-A____P14
Émetteur (câble à connecteur simple (2 câbles par ensemble, pour l'émetteur et le récepteur))Auxiliary output 2: Turns ON when the point of 30,000 operating hours is reached (Operation mode can be changed with the setting tool.)External indicator output 2 : ON when lock-out for a basic system (Operation mode can be changed with the setting tool.)ON when muting/override for a muting system (Operation mode can be changed with the setting tool.)
Version (Câble à connecteur unique (2 câbles par jeu, pour l'émetteur et le récepteur))Ver. 2
Récepteur (câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))To 50 beams: 68 mA max., 51 to 100 beams: 90 mA max., 101 to 150 beams: 111 mA max.,151 to 180 beams: 128 mA max., 201 to 234 beams: 142 mA max.
OFF à ON (Câble de connexion à une seule extrémité (2 câbles par ensemble, pour l'émetteur et le récepteur))1 set,0245 to 983: 44 ms to 70 ms max.1,055 or higher: 80 ms to 100 ms max.
Aspect (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))Output
Type de capteur (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))Type 4 safety light curtain
Écart de faisceau (P) (Câble de connexion à une seule extrémité (2 câbles par ensemble, pour l'émetteur et le récepteur))9 mm
Diamètre de la lentille (Câble de connexion à une seule extrémité (2 câbles par ensemble, pour l'émetteur et le récepteur))Diameter 5 mm
Portée de fonctionnement (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))0.2 to 9 m (protective height 1,640 mm max.), 0.2 to 7 m (protective height 1,655 mm min.)(Depending on the setting tool, the detection distance can be shortened to 0.5 m.)
Catégorie de sécurité (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))Safety purpose of category 4, 3, 2, 1, or B
Nombre de faisceaux (n) (Câble de connexion à une seule extrémité (2 câbles par ensemble, pour l'émetteur et le récepteur))26 to 180
Capacité de détection (câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))Opaque objects 14 mm in diameter
Temps d'attente au démarrage (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))2 s max. (2.2 s max. for series connection)
Utilisation d'une lampe à incandescence pour la sortie auxiliaire et la sortie d'indicateur externe (F3SJ-A____P14/P30)45 m
Mode de fonctionnement de sortie (câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))Receiver
Sorties de sécurité (OSSD) (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),allowable capacity load 2.2 μF, leak current 1 mA max.(This can be different from traditional logic (ON/OFF) because safety circuit is used.)
Hauteur de protection (PH) (Câble à connecteur simple (2 câbles par ensemble, pour l'émetteur et le récepteur))245 to 1,631 mm
Connexion de l'outil de réglage (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))Connectable
Tension d'alimentation (Vs) (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))24 VDC±20% (ripple p-p10% max.)
Consommation de courant (à vide) (Câble à connecteur unique (2 câbles par jeu, pour l'émetteur et le récepteur))Emitter
Angle d'ouverture effectif (EAA) (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))Based on IEC 61496-2.Within±2.5° for both emitter and receiver when the detection distance is 3 m or over
Source lumineuse (longueur d'onde émise) (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))Infrared LED (870 nm)
Sortie auxiliaire 1 (sortie non sécurisée) (câble à connecteur unique (2 câbles par jeu, pour l'émetteur et le récepteur))One PNP transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),leak current 1 mA max.
Sortie d'indicateur externe (sortie non sécurisée) (câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))Available indicatorsIncandescent lamp : 24 VDC, 3 to 7 WLED lamp: Load current 10 mA to 300 mA max., leak current 1 mA max.(To use an external indicator, an F39-JJ3N universal indicator cable or an F39-A01P-PAC dedicated external indicator kit is required.)
Temps de réponse (dans des conditions d'éclairage stables) (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur))ON to OFF
Sortie auxiliaire 2 (Sortie non sécurisée. Fonction pour système de base.) (Câble à connecteur unique (2 câbles par jeu, pour émetteur et récepteur))One PNP transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),leak current 1 mA max.

Description du produit

More details
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Détails techniques

Application

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top