| Paramètre | Valeur |
|---|---|
| 1 631 (F3SJ-A____P14/P30) | 180 |
| Modèle (F3SJ-A____P14/P30) | Protected height (mm) |
| Matériel (F3SJ-A____P14/P30) | Casing (including metal parts on both ends): Aluminum, zinc die-castCap: ABS resin, Optical cover: PMMA resin (acrylic), Cable: Oil resistant PVC |
| Récepteur (F3SJ-A____P14/P30) | Light intensity level indicators (green LED × 2, orange LED × 3): ON based on the light intensityError mode indicators (red LED × 3): Blink to indicate error detailsOFF output indicator (red LED × 1): ON when safety output is OFF, blinks at lockout.ON output indicator (green LED × 1): ON while safety output is ONMuting error indicator, Blanking/test indicator (green LED × 2): ON/flash according to function |
| Condition (F3SJ-A____P14/P30) | 1 set |
| Indicateur (F3SJ-A____P14/P30) | Emitter |
| 281 à 389 (F3SJ-A____P14/P30) | 30 to 42 |
| 407 à 497 (F3SJ-A____P14/P30) | 44 to 54 |
| 420 à 720 (F3SJ-A____P14/P30) | 17 to 29 |
| 515 à 605 (F3SJ-A____P14/P30) | 56 to 66 |
| 623 à 731 (F3SJ-A____P14/P30) | 68 to 80 |
| 767 à 983 (F3SJ-A____P14/P30) | 84 to 108 |
| Accessoires (F3SJ-A____P14/P30) | Test rod (*1), instruction manual, standard mounting bracket (F39-LJ1 bracket for top/bottom mounting), mounting brackets (intermediate) (*2), error mode label, User's Manual (CD-ROM)*1. The F3SJ-A☐☐☐☐55 is not included.*2. Number of intermediate brackets depends on protective height of F3SJ.For protective height from 600 to 1,130 mm : 1 set for each of the emitter and receiver is includedFor protective height from 1,136 to 1,658 mm: 2 sets for each of the emitter and receiver are includedFor protective height from 1,660 to 2,180 mm : 3 sets for each of the emitter and receiver are includedFor protective height from 2,195 to 2,500 mm : 4 sets for each of the emitter and receiver are included |
| 745 à 1 045 (F3SJ-A____P14/P30) | 30 to 42 |
| Tension d'entrée (F3SJ-A____P14/P30) | Test input, interlock selection input, reset input, and muting input are allON voltage: 9 to 24 V (Vs) (sink current: 3 mA max.), OFF voltage: 0 to 1.5 V, or openExternal device monitoring inputON voltage: 9 to 24 V (Vs) (sink current: 5 mA max.), OFF voltage: 0 to 1.5 V, or open |
| Fonction de test (F3SJ-A____P14/P30) | Self test (at power-ON and at power distribution)External test (emission stop function by test input) |
| 1 055 à 1 271 (F3SJ-A____P14/P30) | 116 to 140 |
| 1 070 à 1 295 (F3SJ-A____P14/P30) | 43 to 52 |
| 1 343 à 1 559 (F3SJ-A____P14/P30) | 148 to 172 |
| 1 395 à 1 620 (F3SJ-A____P14/P30) | 56 to 65 |
| 1 745 à 1 995 (F3SJ-A____P14/P30) | 70 to 80 |
| 2 120 à 2 495 (F3SJ-A____P14/P30) | 85 to 100 |
| 10 (Spécifications et informations de commande) | 245 |
| 12 (Spécifications et informations de commande) | 295 |
| 16 (Spécifications et informations de commande) | 395 |
| 19 (Spécifications et informations de commande) | 470 |
| 21 (Spécifications et informations de commande) | 520 |
| 22 (Spécifications et informations de commande) | 545 |
| 23 (Spécifications et informations de commande) | 570 |
| 25 (Spécifications et informations de commande) | 620 |
| 26 (Spécifications et informations de commande) | 245 |
| 28 (Spécifications et informations de commande) | 263 |
| 29 (Spécifications et informations de commande) | 720 |
| 32 (Spécifications et informations de commande) | 795 |
| 34 (Spécifications et informations de commande) | 317 |
| 35 (Spécifications et informations de commande) | 870 |
| 37 (Spécifications et informations de commande) | 920 |
| 38 (Spécifications et informations de commande) | 945 |
| 41 (Spécifications et informations de commande) | 1,020 |
| 42 (Spécifications et informations de commande) | 389 |
| 44 (Spécifications et informations de commande) | 1,095 |
| 45 (Spécifications et informations de commande) | 1,120 |
| 48 (Spécifications et informations de commande) | 1,195 |
| 50 (Spécifications et informations de commande) | 461 |
| 51 (Spécifications et informations de commande) | 1,270 |
| 56 (Spécifications et informations de commande) | 1,395 |
| 60 (Spécifications et informations de commande) | 551 |
| 65 (Spécifications et informations de commande) | 1,620 |
| 68 (Spécifications et informations de commande) | 623 |
| 70 (Spécifications et informations de commande) | 1,745 |
| 75 (Spécifications et informations de commande) | 1,870 |
| 76 (Spécifications et informations de commande) | 695 |
| 80 (Spécifications et informations de commande) | 1,995 |
| 88 (Spécifications et informations de commande) | 803 |
| 90 (Spécifications et informations de commande) | 2,245 |
| 95 (Spécifications et informations de commande) | 2,370 |
| 96 (Spécifications et informations de commande) | 875 |
| 100 (Spécifications et informations de commande) | 2,495 |
| 108 (Spécifications et informations de commande) | 983 |
| 116 (Spécifications et informations de commande) | 1,055 |
| 124 (Spécifications et informations de commande) | 1,127 |
| 132 (Spécifications et informations de commande) | 1,199 |
| 140 (Spécifications et informations de commande) | 1,271 |
| Humidité ambiante (F3SJ-A____P14/P30) | Operating: 35% to 85% (no condensation), Storage: 35% to 95% |
| Résistance aux chocs (F3SJ-A____P14/P30) | Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions |
| Méthode de connexion (F3SJ-A____P14/P30) | Connector method (M12, 8-pin) |
| Connexion en série (F3SJ-A____P14/P30) | Time division emission by series connectionNumber of connections: up to 4 sets (F3SJ-A only) F3SJ-E, F3SJ-B and F3SJ-TS cannot be connected.Total number of beams: up to 400 beamsMaximum cable length for 2 sets: no longer than 15 m |
| Poids (emballé) (F3SJ-A____P14/P30) | Calculate using the following expressions:(1) For F3SJ-A____14, weight (g) = (protective height) x 1.7 +α(2) F3SJ-A____30, weight (g) = (protective height) x 1.5 +αThe values forαare as follows:Protected height 245 to 596 mm: = 1,100 protected height 1,660 to 2,180 mm: = 2,400Protected height 600 to 1,130 mm: = 1,500 protected height 2,195 to 2,500 mm: = 2,600Protected height 1,136 to 1,658 mm: = 2,000 |
| Tension de tenue (F3SJ-A____P14/P30) | 1,000 VAC 50/60 Hz, 1 min |
| Circuit de protection (F3SJ-A____P14/P30) | Output short-circuit protection, and power supply reverse polarity protection |
| Température ambiante (F3SJ-A____P14/P30) | Operating: -10 to 55°C (no icing), Storage: -30 to 70°C |
| Série F3SJ-A____14 (F3SJ-A____P14/P30) | 245 to 263 |
| Série F3SJ-A____30 (F3SJ-A____P14/P30) | 245 to 395 |
| Normes applicables (F3SJ-A____P14/P30) | IEC 61496-1, EN 61496-1 UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment)IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices)IEC 61508-1 to -3, EN 61508-1 to -3 SIL3IEC 13849-1: 2006, EN ISO 13849-1: 2008 (PLe, Cat.4)UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
| Degré de protection (F3SJ-A____P14/P30) | IP65 (IEC 60529) |
| Résistance aux vibrations (F3SJ-A____P14/P30) | Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions |
| résistance d'isolement (F3SJ-A____P14/P30) | 20 MΩ min. (at 500 VDC) |
| 0,2 à 7 m (Spécifications et informations de commande) | 1,745 to 2,495 |
| Application (Spécifications et informations de commande) | Detection capability |
| Fonctions liées à la sécurité (F3SJ-A____P14/P30) | Start interlock, restart interlock (Must be set with a setting tool when the muting function is used.)External device monitorMuting (Lamp burnout detection, override function included. F39-CN6 key cap for muting is required.)Fixed blanking (must be set by a setting tool)Floating blanking (must be set by a setting tool) |
| Lampe à incandescence non utilisée (F3SJ-A____P14/P30) | 100 m |
| Nombre de poutres (Spécifications et informations de commande) | Protective height (mm)2 |
| Protection des doigts (Spécifications et informations de commande) | Dia. 14 mm |
| Protection des mains et des bras (Spécifications et informations de commande) | Dia. 30 mm |
| Intensité lumineuse ambiante de fonctionnement (F3SJ-A____P14/P30) | Incandescent lamp: receiving-surface light intensity of 3,000 lx max., Sunlight: receiving-surface light intensity of 10,000 lx max. |
| Fonction de prévention des interférences mutuelles (F3SJ-A____P14/P30) | Interference light prevention algorithm, sensing distance change function |
| (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | Laser pointer for F3SJ |
| Utilisation d'une lampe à incandescence pour la sortie d'indicateur externe 1 (F3SJ-A____P14/P30) | 60 m |
| Utilisation d'une lampe à incandescence pour la sortie d'indicateur externe 2 (F3SJ-A____P14/P30) | 40 m |
| 7 m (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | F39-JD7A |
| 10 m (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | F39-JD10A |
| 15 m (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | F39-JD15A |
| 20 m (Câble à connecteur unique (2 câbles par jeu, pour l'émetteur et le récepteur)) | F39-JD20A |
| Modèle (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | F3SJ-A____P14 |
| Émetteur (câble à connecteur simple (2 câbles par ensemble, pour l'émetteur et le récepteur)) | Auxiliary output 2: Turns ON when the point of 30,000 operating hours is reached (Operation mode can be changed with the setting tool.)External indicator output 2 : ON when lock-out for a basic system (Operation mode can be changed with the setting tool.)ON when muting/override for a muting system (Operation mode can be changed with the setting tool.) |
| Version (Câble à connecteur unique (2 câbles par jeu, pour l'émetteur et le récepteur)) | Ver. 2 |
| Récepteur (câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | To 50 beams: 68 mA max., 51 to 100 beams: 90 mA max., 101 to 150 beams: 111 mA max.,151 to 180 beams: 128 mA max., 201 to 234 beams: 142 mA max. |
| OFF à ON (Câble de connexion à une seule extrémité (2 câbles par ensemble, pour l'émetteur et le récepteur)) | 1 set,0245 to 983: 44 ms to 70 ms max.1,055 or higher: 80 ms to 100 ms max. |
| Aspect (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | Output |
| Type de capteur (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | Type 4 safety light curtain |
| Écart de faisceau (P) (Câble de connexion à une seule extrémité (2 câbles par ensemble, pour l'émetteur et le récepteur)) | 9 mm |
| Diamètre de la lentille (Câble de connexion à une seule extrémité (2 câbles par ensemble, pour l'émetteur et le récepteur)) | Diameter 5 mm |
| Portée de fonctionnement (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | 0.2 to 9 m (protective height 1,640 mm max.), 0.2 to 7 m (protective height 1,655 mm min.)(Depending on the setting tool, the detection distance can be shortened to 0.5 m.) |
| Catégorie de sécurité (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | Safety purpose of category 4, 3, 2, 1, or B |
| Nombre de faisceaux (n) (Câble de connexion à une seule extrémité (2 câbles par ensemble, pour l'émetteur et le récepteur)) | 26 to 180 |
| Capacité de détection (câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | Opaque objects 14 mm in diameter |
| Temps d'attente au démarrage (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | 2 s max. (2.2 s max. for series connection) |
| Utilisation d'une lampe à incandescence pour la sortie auxiliaire et la sortie d'indicateur externe (F3SJ-A____P14/P30) | 45 m |
| Mode de fonctionnement de sortie (câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | Receiver |
| Sorties de sécurité (OSSD) (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),allowable capacity load 2.2 μF, leak current 1 mA max.(This can be different from traditional logic (ON/OFF) because safety circuit is used.) |
| Hauteur de protection (PH) (Câble à connecteur simple (2 câbles par ensemble, pour l'émetteur et le récepteur)) | 245 to 1,631 mm |
| Connexion de l'outil de réglage (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | Connectable |
| Tension d'alimentation (Vs) (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | 24 VDC±20% (ripple p-p10% max.) |
| Consommation de courant (à vide) (Câble à connecteur unique (2 câbles par jeu, pour l'émetteur et le récepteur)) | Emitter |
| Angle d'ouverture effectif (EAA) (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | Based on IEC 61496-2.Within±2.5° for both emitter and receiver when the detection distance is 3 m or over |
| Source lumineuse (longueur d'onde émise) (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | Infrared LED (870 nm) |
| Sortie auxiliaire 1 (sortie non sécurisée) (câble à connecteur unique (2 câbles par jeu, pour l'émetteur et le récepteur)) | One PNP transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),leak current 1 mA max. |
| Sortie d'indicateur externe (sortie non sécurisée) (câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | Available indicatorsIncandescent lamp : 24 VDC, 3 to 7 WLED lamp: Load current 10 mA to 300 mA max., leak current 1 mA max.(To use an external indicator, an F39-JJ3N universal indicator cable or an F39-A01P-PAC dedicated external indicator kit is required.) |
| Temps de réponse (dans des conditions d'éclairage stables) (Câble à connecteur unique (2 câbles par ensemble, pour l'émetteur et le récepteur)) | ON to OFF |
| Sortie auxiliaire 2 (Sortie non sécurisée. Fonction pour système de base.) (Câble à connecteur unique (2 câbles par jeu, pour émetteur et récepteur)) | One PNP transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),leak current 1 mA max. |
Spécifications techniques et données de performance