Heures de service : Lundi à vendredi 9h00-18h00
UDPHL154 - UDPHL154 DPH-L154 PANASONIC Sensor head DPH-L154 for positive pressure, 0 to 50MPa, R1/4 male thread, cable ..
En stock Produit phare

UDPHL154

UDPHL154 DPH-L154 PANASONIC Sensor head DPH-L154 for positive pressure, 0 to 50MPa, R1/4 male thread, cable ..

$0.00USD
4853 en stock
Spécifications clés
Article:Specifications
Câble:0.2 mm23-core heat resistant cabtyre cable 2 m3.562 ftlong
Remarque:Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃+73.4 ℉.The sensor head can be used independently.Oil is used in the factory inspection process for models DPH-L114 and DPH-L154. There may be some residual oil inside the pressure port.
Poids:Net weight : 100 g approx., Gross weight : 150 g approx.
Informations sur le fournisseur
PANASONIC
PANASONIC
Produits : 4316
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
ArticleSpecifications
Câble0.2 mm23-core heat resistant cabtyre cable 2 m3.562 ftlong
RemarqueWhere measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃+73.4 ℉.The sensor head can be used independently.Oil is used in the factory inspection process for models DPH-L114 and DPH-L154. There may be some residual oil inside the pressure port.
PoidsNet weight : 100 g approx., Gross weight : 150 g approx.
DétailsSensor head
ProduitHead-separated Dual display Digital Pressure Sensor [For gas & liquid]
MatérielDiaphragm : Stainless steel (SUS603), Pressure port : Stainless steel (SUS304), Throttle : Stainless steel (SUSXM7)
ProtectionIP67 (IEC)
AccessoiresConnector (e-CON) : 1 pc.
Numéro de pièceDPH-L154
Nom du produitHead-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100
orifice de pressionR1/4 male thread (throttle embeded)
temps de réponse1 ms or less
Numéro de produitDPH-L154
Tension d'alimentation9 to 36 V DC[9 to 32 V DC when using the attached connector (e-CON)]
rallonge de câbleExtension up to total 10 m32.808 ftis possible with 0.2 mm2, or more, cable.
Humidité ambiante35 to 85 % RH, Storage : 35 to 85 % RH
Fluide applicableGases and fluids that do not corrode stainless steel SUS630, SUS304, or SUSXM7
Méthode de mise à la terreCapacitor earth (Enclosure-supply terminal)
résistance aux chocs1,000 m/s2acceleration in X, Y and Z directions three times each
Type de pressionSealed gauge pressure(Note): The sensor's internal mechanism is sealed based on an air pressure of 1,013 hPa.
Méthode de connexionConnector
Température ambiante-20 to +80 ℃ (Pressure port: -20 to +125 ℃\n-4 to +257 ℉, No dew condensation or icing allowed),\n Storage: -30 to +100 ℃-22 to +212 ℉\n[e-CON connector (accesory):-20 to +75 ℃\n-4 to +167 ℉\n(Storage: -30 to +75 ℃-22 to +167 ℉)]
Consommation de courant20 mA or less
Plage de pression nominale0 to +50 MPa
résistance aux vibrations10 to 2,000 Hz frequency, acceleration 200 m/s2, in X direction for four hours, in Y and Z directions for two hours each(Note): The X, Y, and Z directions are defined as follows :
Sortie de tension analogiqueOutput voltage: 1 to 5 V DC (over rated pressure range)\n Accuracy: ±1.0 % F.S. (at 23 ±2 ℃+73.4 ±35 ℉)\n ±2.0 % F.S. (at -20 to 125 ℃-4 to +257 ℉)\n (including linearity, hysteresis and repeatability)
résistance d'isolation100 MΩ, or more, with 50 V DC megger between all supply terminals connected together and enclosure
Réglementation applicableCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Plage de températures moyennes-20 to +125 ℃-4 to +257 ℉
tenue en tension150 V AC for one min. between all supply terminals connected together and enclosure
résistance à la pression75 MPa

Description du produit

Sensor head, positive pressure. 0 to 50MPa. R1/4 male pressure port.
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top