Heures de service : Lundi à vendredi 9h00-18h00
UGXHL15AP - UGXHL15AP GX-HL15A-P PANASONIC Inductive proximity sensor, rectangular type, 8.0mm, top sensing, PNP, NO, IP..
En stock Produit phare

UGXHL15AP

UGXHL15AP GX-HL15A-P PANASONIC Inductive proximity sensor, rectangular type, 8.0mm, top sensing, PNP, NO, IP..

$0.00USD
3787 en stock
Spécifications clés
Article:Specifications
Câble:0.15 mm23-core oil, heat and cold resistant cabtyre cable, 1 m3.281 ftlong
Sortir:PNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less(between output and +V)- Residual voltage: 2 V or less (at 100 mA source current)
Détails:PNP output
Informations sur le fournisseur
PANASONIC
PANASONIC
Produits : 4316
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
ArticleSpecifications
Câble0.15 mm23-core oil, heat and cold resistant cabtyre cable, 1 m3.281 ftlong
SortirPNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less(between output and +V)- Residual voltage: 2 V or less (at 100 mA source current)
DétailsPNP output
ProduitRectangular-shaped Inductive Proximity Sensor
MatérielEnclosure: PBTIndicator part: Polyester
Hystérèse20 % or less of operation distance(with standard sensing object)
Poids net20 g approx.
ProtectionIP68 (IEC), IP68g (JEM)(Note) Panasonic Electric Works SUNX's IP68 test method1. Immerse at 0 m below 0 ℃+32 ℉water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃+158 ℉water surface and leave for 30 min.2. Regard the heat shock test in 1 as one cycle and perform 20 cycles.3. Leave in water at a depth of 1 m3.281 ftin water for 500 hours.4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values.(Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Numéro de pièceGX-HL15A-P
Nom du produitRectangular-shaped Inductive Proximity Sensor GX-F/H
RépétabilitéAlong sensing axis, perpendicular to sensing axis: 0.04 mm0.002 inor less
Numéro de produitGX-HL15A-P
Tension d'alimentation12 to 24 V DC +10/-15 % Ripple P-P 10 % or less
rallonge de câbleExtension up to total 100 m328.084 ftis possible with 0.3 mm2, or more, cable.
Humidité ambiante45 to 85 % RH, Storage: 35 to 95 % RH
résistance aux chocs10,000 m/s2acceleration (1,000 G approx.) in X, Y and Z directions three times each
Température ambiante-25 to +70 ℃-13 to +158 ℉, Storage: - 40 to +85 ℃- 40 to +185 ※
Consommation de courant15 mA or less
Indicateur de fonctionnementOrange LED(lights up when the output is ON)
Portée de détection stable0 to 6.7 mm0 to 0.264 in(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.(Note) This is when mounted onto an insulant plate. When mounted onto a steel or stainless steel plate, insert the optional aluminum sheet between the sensor and the plate.
résistance aux vibrations10 to 500 Hz frequency, 3 mm0.118 indouble amplitude (Max. 20 G) in X, Y and Z directions for two hours each
résistance d'isolation50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Distance de fonctionnement maximale8.0 mm0.315 inplus or minus 8 %(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.(Note) This is when mounted onto an insulant plate. When mounted onto a steel or stainless steel plate, insert the optional aluminum sheet between the sensor and the plate.
Fréquence de réponse maximale150 Hz(Note) This is when mounted onto an insulant plate. When mounted onto a metallic plate, max. response frequency will decrease.
Sortie : Opération de sortieNormally open
Objet de détection standardIron sheet 30 × 30 × t 1 mm1.181 × 1.181 × t 0.039 in
tenue en tension1,000 V AC for one min. between all supply terminals connected together and enclosure
Résultat : Catégorie d'utilisationDC-12 or DC-13
Réglementations et certifications applicablesCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Variation de la plage de détection : caractéristiques de tensionWithin plus or minus 2 % for +10/-15 % fluctuation of the supply voltage
Variation de la plage de détection : caractéristiques de températureOver ambient temperature range -25 to +70 ℃-13 to +158 ℉: Within plus or minus 8 % of sensing range at +23 ℃+73 ℉

Description du produit

Rectangular proximity detector, front detection, 8.0 mm. NA, PNP
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation